09/21/2006

By Bolstad-Johnson DM, Burgess JL, Crutchfield CD, Storment S, Gerkin R, Wilson JR.
AIHAJ: A Journal for the Science of Occupational and Environmental Health and Safety. 2000 Sep-Oct;61(5):636-41.

Previous studies have characterized firefighter exposures during fire suppression. However, minimal information is available regarding firefighter exposures during overhaul, when firefighters look for hidden fire inside attics, ceilings, and walls, often without respiratory protection. A comprehensive air monitoring study was conducted to characterize City of Phoenix firefighter exposures during the overhaul phase of 25 structure fires.

Personal samples were collected for aldehydes; benzene; toluene; ethyl benzene; xylene; hydrochloric acid; polynuclear aromatic hydrocarbons (PNA); respirable dust; and hydrogen cyanide (HCN). Gas analyzers were employed to continuously monitor carbon monoxide (CO), HCN, nitrogen dioxide (NO2), and sulfur dioxide (SO2). Area samples were collected for asbestos, metals (Cd, Cr, Pb), and total dust. During overhaul the following exceeded published ceiling values: acrolein (American Conference of Governmental Industrial Hygienists [ACGIH] 0.1 ppm) at 1 fire; CO (National Institute for Occupational Safety and Health [NIOSH] 200 ppm) at 5 fires; formaldehyde (NIOSH 0.1 ppm) at 22 fires; and glutaraldehyde (ACGIH 0.05 ppm) at 5 fires. In addition, the following exceeded published short-term exposure limit values: benzene (NIOSH 1 ppm) at two fires, NO2 (NIOSH 1 ppm) at two fires, and SO2 (ACGIH 5 ppm) at five fires. On an additive effects basis, PNA concentrations exceeded the NIOSH recommended exposure limits (0.1 mg/M3) for coal tar pitch volatiles at two fires. Maximum concentrations of other sampled substances were below their respective permissible exposure limits. Initial 10-min average CO concentrations did not predict concentrations of other products of combustion.

The results indicate that firefighters should use respiratory protection during overhaul. In addition, these findings suggest that CO should not be used as an indicator gas for other contaminants found in this atmosphere.




Back to previous page


Sponsored By
This site is sponsored by Masimo, the manufacturer of Rad-57, the first non-invasive way of measuring CO in the blood. Request Information
Watch a video demo of the Rad-57™

Press Releases
FDNY Makes Largest First Responder Purchase of Masimo Rad-57 Pulse CO-Oximeters to Improve Survival of Firefighters and Victims of Carbon Monoxide Poisoning 343 Technologies and Hothead Technologies Announce Wireless Temperature Sensor for Firefighter Rehab Masimo and Physio-Control Release New Grants Supplement for Fire and EMS Departments
More Press Releases 

FireRescue Exclusive

Lethal Exposure 

Copyright 2010
Masimo  FireRescue1  About This Site  Privacy Policy 
Login          My profile 
Powered by: