Spread the Word Bookmark
Search:  
         
Login     My Profile
Clinical Studies

Environmental study of firefighters

09/21/2006

By Jankovic J, Jones W, Burkhart J, Noonan G.
The Annals of Occupational Hygiene. 1991 Dec;35(6):581-602.

A study of firefighter exposures was undertaken at the request of the U.S. Fire Administration. This work was part of a larger study which included field evaluation of the performance of the self-contained breathing apparatus (SCBA) worn by firefighters during structural firefighting. Measurements were made for a variety of contaminants including CO, CO2, benzene, HCN, HCl, H2SO4, HF, acrolein, CH4, formaldehyde and PNAs.

Many of the analyses were performed by collection of bag samples followed by Fourier transform infrared spectroscopy using a field mobile spectrometer. Measurements were also made using solid sorbent tubes and direct-reading meters. Sampling was done both during the knockdown and during overhaul phases of structural firefighting. Also, in order to estimate exposures including those when the SCBAs were worn, measurements were made both inside and outside the SCBA facepiece.

Carbon monoxide was the most common contaminant found during knockdown, and about 10% of the samples were greater than 1500 ppm. Formaldehyde, acrolein, hydrogen chloride, hydrogen cyanide, sulphuric acid and hydrogen fluoride all exceeded their respective short-term exposure limits (STEL) on some occasions. Approximately 50% of the knockdown samples for acrolein exceeded the STEL. During overhaul, when masks were usually not worn, many of the contaminants found during knockdown were detected, but typically at much lower concentrations. Inside-mask sampling data suggest that exposure to low concentrations of a variety of compounds is occurring but this is believed to be principally the result of early mask removal or of non-use during knockdown rather than of leakage. The three basic sampling approaches (bag sampling, sorbent tubes and direct-reading meters) proved in this study to be complementary and served to maximize our ability to detect and quantify a wide range of combustion products.




Back to previous page


Sponsored By
This site is sponsored by Masimo, the manufacturer of Rad-57, the first non-invasive way of measuring CO in the blood. Request Information
Watch a video demo of the Rad-57™

Press Releases
FDNY Makes Largest First Responder Purchase of Masimo Rad-57 Pulse CO-Oximeters to Improve Survival of Firefighters and Victims of Carbon Monoxide Poisoning 343 Technologies and Hothead Technologies Announce Wireless Temperature Sensor for Firefighter Rehab Masimo and Physio-Control Release New Grants Supplement for Fire and EMS Departments
More Press Releases 

FireRescue Exclusive

Lethal Exposure 

Copyright 2010
Masimo  FireRescue1  About This Site  Privacy Policy 
Login          My profile 
Powered by: