NIOSH fatality report stresses medical monitoring of trainees


By FireRescue1 Staff

DALE CITY, Va. — The importance of incorporating medical monitoring of trainees into rehab programs has been stressed in a NIOSH firefighter fatality report.

EMT Cecilia Turnbough suffered sudden cardiac death during firefighter maze training at the Public Safety Training Center in Dale City on November 9 last year.

The report into her death also recommends that training maze props or trailers used in SCBA confidence training have adequate safety features such as emergency egress panels, emergency lighting and ventilation.

After completing the hose maze evolution, the report said Turnbough was tired and sweating heavily. After lunch, she began the maze portion and completed approximately half of the exercise when her SCBA low-air alarm sounded, it added.

She informed the instructor that she wanted to continue, but after entering the next portion of the maze and crawling up a slight incline, she did not turn around and back down the decline as required.

The instructor saw that something was wrong and spoke to the Turnbough but received no response, the report said. At this time, Turnbough's personal alert safety system alarm sounded, but it took instructors about 10 minutes to remove her from the maze.

Paramedics began advanced life support and transported her to a local hospital, but efforts to revive her were unsuccessful.

"In this incident, all participants should have been assigned to rehabilitation after the hose maze drill," the report said. "Perhaps if the Trainee had gone to rehabilitation and her vital signs (including pulse oximetry) were checked, an abnormality might have been detected. This may have led to the Trainee being referred for further medical diagnosis/treatment."

Among the NIOSH recommendations in the report are:

• Conduct all SCBA training in accordance with NFPA 1404, Standard for Fire Service Respiratory Protection Training

• Have adequate safety features for training maze props or trailers used in SCBA confidence training, including emergency egress panels, emergency lighting, ventilation, and a temperature monitoring system to measure the ambient temperature inside the maze

• Provide firefighters with medical clearance to wear a self-contained breathing apparatus as part of the Fire Department's medical evaluation program

• Provide preplacement and annual medical evaluations to firefighters

• Incorporate medical monitoring of trainees into rehabilitation programs

• Educate firefighters to report signs and symptoms consistent with a heart attack to appropriate authorities for prompt medical evaluation

• Perform a preplacement and an annual physical performance (physical ability) evaluation

• Ensure firefighters are cleared for return to duty by a physician knowledgeable about the physical demands of firefighting, the personal protective equipment used by firefighters, and the various components of NFPA 1582

• Phase in a comprehensive wellness and fitness program for firefighters











Back to previous page


 Most Popular
Making Rehab a Requirement: NFPA 1584 CorTemp heats up Rehab chair gets to the core of heat stress SCBA 'flat pack' prototype expected in September DC firefighters focus on hydration during heat wave
All Popular Articles 


FireRehab Communications
FireRehab Communications - May- Volume 21 FireRehab Communications - March- Volume 20
All Newsletters
Resources

USFA Emergency Incident Rehabilitation Manual IAFC: Fighting Heat Stress U.S. EPA Excessive Heat Events Guidebook (PDF) Agency for Toxic Substances Cyanide FAQ Assistance to Firefighters Grant AFG: DHS/FEMA Fire Act Grant
All Resources 

Press Releases
FDNY Makes Largest First Responder Purchase of Masimo Rad-57 Pulse CO-Oximeters to Improve Survival of Firefighters and Victims of Carbon Monoxide Poisoning 343 Technologies and Hothead Technologies Announce Wireless Temperature Sensor for Firefighter Rehab Masimo and Physio-Control Release New Grants Supplement for Fire and EMS Departments
More Press Releases 

Sponsored By
This site is sponsored by Masimo, the manufacturer of Rad-57, the first non-invasive way of measuring CO in the blood. Request Information
Watch a video demo of the Rad-57™


Copyright 2010
Masimo  FireRescue1  About This Site  Privacy Policy 
Login          My profile 
Powered by: